651 research outputs found

    Virtual Instruments in Dimensional Metrology

    Get PDF
    During the last five years, in order to improve understanding of content related to "Coordinate Metrology", the Laboratorio de Metrología y Metrotecnia (LMM) from the Polytechnic University of Madrid offers its PhD students, as a course work, the construction of a virtual instrument. This virtual instrument simulates the imaging of a part to be measured by optical dimensional metrology instruments (microscopes, profile projectors, vision machines). The LMM provides students with images similar to those they would obtain with real instrumentation for the instrument adjustment and calibration process. Working with these images, students should determine the adjustment parameters of the virtual instrument. Once these parameters are set, the student can perform the proper calibration of the virtual instrument. Beyond this process, the instrument is already able to perform traceable measurement. In order to do that, LMM offers students some images of parts. Students should perform some measurements using those images and estimate the corresponding uncertainties

    Molecular simulation of methane hydrate growth confined into a silica pore

    Get PDF
    Financiaciado para publicación en acceso aberto: Universidade de Vigo/CISUGThe growth of a methane hydrate seed within a silica slit pore of fixed width has been studied using All- Atom Molecular Dynamics (AA-MD). An AA force field has been used to describe the molecules of the solid silica substrate, with a-quartz crystalline structure. The crystallisation of hydrates in confined geometries is not well understood yet, and the objective of this work is to study the hydrate growth inside a silica pore using molecular simulation. Both NVT and NpT ensembles were used in the AA-MD simulations to analyse the hydrate growth from an initial seed. Results showed that the boundary conditions imposed by the nanometric slit pore yielded a hydrate with structural defects, filling the accessible space between the silica walls. The water molecules which were not incorporated to the initial seed hydrate formed a high density water layer trapped between the silica walls and the crystallised hydrate. These results provide an interesting insight into the hydrate crystallisation process in confined geometries, resembling those found in natural hydrate deposits.Ministerio de Ciencia e Innovación | Ref. PID2021-125081NB-I00FEDER | Ref. SOE2/P1/P0823Xunta de Galicia | Ref. FSE-GALICIA 2014–2020Fundação para a Ciência e a Tecnologia | Ref. UIDB/50011/2020Fundação para a Ciência e a Tecnologia | Ref. UIDP/50011/2020Fundação para a Ciência e a Tecnologia | Ref. LA/ P/0006/2020Ministerio de Ciencia e Innovación | Ref. PID2019-105898GA-C22Comunidad de Madrid | Ref. APOYOJOVENES- 01HQ1S-129-B5E4M

    Uncertainty in ellipse fitting using a flatbed scanner: development and experimental verification

    Full text link
    In the field of dimensional metrology, the use of optical measuring machines requires the handling of a large number of measurement points, or scanning points, taken from the image of the measurand. The presence of correlation between these measurement points has a significant influence on the uncertainty of the result. The aim of this work is the development of an estimation procedure for the uncertainty of measurement in a geometrically elliptical shape, taking into account the correlation between the scanning points. These points are obtained from an image produced using a commercial flat bed scanner. The characteristic parameters of the ellipse (coordinates of the center, semi-axes and the angle of the semi-major axis with regard to the horizontal) are determined using a least squares fit and orthogonal distance regression. The uncertainty is estimated using the information from the auto-correlation function of the residuals and is propagated through the fitting algorithm according to the rules described in Evaluation of Measurement Data—Supplement 2 to the ‘Guide to the Expression of Uncertainty in Measurement’—Extension to any number of output quantities. By introducing the concept of cut-off length, it can be observed how it is possible to take into account the presence of the correlation in the estimation of uncertainty in a very simple way while avoiding underestimation

    Análisis de Tensiones Residuales Inducidas en Aleaciones Metálicas por Tratamientos Superficiales mediante Ondas de Choque Generadas por Láser

    Get PDF
    En el presente artículo se plantea un estudio sobre la medida de tensiones residuales mediante el método del taladro en banda extensométrica (o agujero ciego) aplicado en probetas de aluminio 2024-T351, previamente tratadas superficialmente mediante laser shock processing (método de tratamiento superficial por ondas de choque generadas por láser, conocido como LSP). Finalmente, se realiza una comparación entre los resultados experimentales obtenidos al medir las tensiones residuales obtenidas en probetas tratadas mediante LSP y los valores obtenidos mediante un modelo de simulación

    Metrología óptica dimensional submicrométrica para determinación de espesores en sub-micro estructuras

    Get PDF
    En este trabajo se presenta el análisis de una técnica de metrología óptica utilizada para el control de procesos en línea en la fabricación de microchips. Se obtienen los perfiles de reflectividad en función del ángulo de incidencia para una longitud de onda de 675 nm, para los estados de polarización s y p. Se obtiene un modelo teórico para una estructura multicapa, con la que se pueden calcular de forma sencilla las propiedades ópticas y dimensiones de las capas. Se obtiene la incertidumbre de la técnica de medida.-In this work is presented the analysis of a technique of optical metrology widely used in controlling on- line process in fabrication of microchips. Reflectivity profiles as a function of angle of incidence are obtained for a wavelength of 675 nm. A theoretical model for a Si/ SiO2 multilayer stack is also obtained, which can be used to calculate both the thickness and the optical properties of the layers. A calculation of the uncertainty for the measurement technique is also performed

    Microconformado de Materiales Metálicos mediante Pulsos Láser en el Dominio de ns

    Get PDF
    La demanda de miniaturización introducida, entre otros, por la industria de fabricación de MEMS (Micro Electro Mechanical Systems), hace necesario caracterizar y validar los procesos que emplean el láser en el microconformado de materiales metálicos a escala submilimétrica. Como alternativa al microconformado térmico, que hace uso de las deformaciones de origen térmico inducidas por la radiación láser, el microconformado mediante pulsos láser en el dominio de ns hace posible el conformado de materiales metálicos manteniendo, o incluso mejorando, las propiedades mecánicas de los mismos debido a la inducción de tensiones residuales de compresión en la superficie de la pieza tratada. Se presenta en este trabajo el estudio teórico y experimental del microconformado láser mediante la caracterización de diversas pruebas elementales. Miniaturization of components demanded by MEMS (Micro Electro Mechanical Systems) industry, makes necessary the validation of the manufacturing processes applied to submillimetric metallic materials in which laser is used. As an alternative to thermal microforming in which laser induced thermal fields are responsible for the forming phenomena, the use of ns laser pulses makes possible microforming of metallic materials preserving, or even improving, their mechanical properties, due to the induction of residual stresses in the surface. In the present paper experimental tests and FEM simulation results on nanosecond time scale laser microforming are presented

    Mechanical behavior of asphalt mixtures containing silica gels as warm additives

    Get PDF
    This paper presents the results of a study of some compounds capable of absorbing water into their structure (silica gel), as potential foaming binders. Asphalt mixtures were manufactured at different manufacturing and compaction temperatures, using four different silica gels. Static and dynamic tests were carried out to determine their behavior in asphalt mixtures. The results were compared with those obtained using hot-mix asphalt and warm-mix asphalt manufactured with zeolite. The lab results showed a similar behavior of asphalt mixtures containing either silica gel or zeolite.The research presented herein was sponsored by the Research Office of Universidad de La Frontera (DIUFRO) under the project number DI15-0089

    Burden of rare variants in synaptic genes in patients with severe tinnitus: An exome based extreme phenotype study

    Get PDF
    Background: tinnitus is a heterogeneous condition associated with audiological and/or mental disorders. Chronic, severe tinnitus is reported in 1% of the population and it shows a relevant heritability, according to twins, adoptees and familial aggregation studies. The genetic contribution to severe tinnitus is unknown since large genomic studies include individuals with self-reported tinnitus and large heterogeneity in the phenotype. The aim of this study was to identify genes for severe tinnitus in patients with extreme phenotype. Methods: for this extreme phenotype study, we used three different cohorts with European ancestry (Spanish with Meniere disease (MD), Swedes tinnitus and European generalized epilepsy). In addition, four independent control datasets were also used for comparisons. Whole-exome sequencing was performed for the MD and epilepsy cohorts and whole-genome sequencing was carried out in Swedes with tinnitus. Findings: we found an enrichment of rare missense variants in 24 synaptic genes in a Spanish cohort, the most significant being PRUNE2, AKAP9, SORBS1, ITGAX, ANK2, KIF20B and TSC2 (p < 2E 04), when they were compared with reference datasets. This burden was replicated for ANK2 gene in a Swedish cohort with 97 tinnitus individuals, and in a subset of 34 Swedish patients with severe tinnitus for ANK2, AKAP9 and TSC2 genes (p < 2E 02). However, these associations were not significant in a third cohort of 701 generalized epilepsy individuals without tinnitus. Gene ontology (GO) and gene-set enrichment analyses revealed several pathways and biological processes involved in severe tinnitus, including membrane trafficking and cytoskeletal protein binding in neurons. Interpretation: a burden of rare variants in ANK2, AKAP9 and TSC2 is associated with severe tinnitus. ANK2, encodes a cytoskeleton scaffolding protein that coordinates the assembly of several proteins, drives axonal branching and influences connectivity in neurons

    Vascular Inflammation in Subclinical Atherosclerosis Detected by Hybrid PET/MRI

    Get PDF
    BACKGROUND: Atherosclerosis is a chronic inflammatory disease, but data on arterial inflammation at early stages is limited. OBJECTIVES: The purpose of this study was to characterize vascular inflammation by hybrid 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/magnetic resonance imaging (PET/MRI). METHODS: Carotid, aortic, and ilio-femoral 18F-FDG PET/MRI was performed in 755 individuals (age 40 to 54 years; 83.7% men) with known plaques detected by 2-/3-dimensional vascular ultrasound and/or coronary calcification in the PESA (Progression of Early Subclinical Atherosclerosis) study. The authors evaluated the presence, distribution, and number of arterial inflammatory foci (increased 18F-FDG uptake) and plaques with or without inflammation (coincident 18F-FDG uptake). RESULTS: Arterial inflammation was present in 48.2% of individuals (24.4% femorals, 19.3% aorta, 15.8% carotids, and 9.3% iliacs) and plaques in 90.1% (73.9% femorals, 55.8% iliacs, and 53.1% carotids). 18F-FDG arterial uptakes and plaques significantly increased with cardiovascular risk factors (p < 0.01). Coincident 18F-FDG uptakes were present in 287 of 2,605 (11%) plaques, and most uptakes were detected in plaque-free arterial segments (459 of 746; 61.5%). Plaque burden, defined by plaque presence, number, and volume, was significantly higher in individuals with arterial inflammation than in those without (p < 0.01). The number of plaques and 18F-FDG uptakes showed a positive albeit weak correlation (r = 0.25; p < 0.001). CONCLUSIONS: Arterial inflammation is highly prevalent in middle-aged individuals with known subclinical atherosclerosis. Large-scale multiterritorial PET/MRI allows characterization of atherosclerosis-related arterial inflammation and demonstrates 18F-FDG uptake in plaque-free arterial segments and, less frequently, within plaques. These findings suggest an arterial inflammatory state at early stages of atherosclerosis. (Progression of Early Subclinical Atherosclerosis [PESA]; NCT01410318).The PESA study is cofunded equally by the Centro Nacional de Investigaciones Cardiovasculares (CNIC) and Banco Santander. The study also receives funding from the Instituto de Salud Carlos III (PI15/02019) and the European Regional Development Fund (ERDF) “A way to make Europe.” The CNIC is supported by the Ministerio de Ciencia, Innovación y Universidades, and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505). Dr. Sanchez-González is an employee of Philips Healthcare. Dr. Bueno has received research funding from the Instituto de Salud Carlos III, Spain (PIE16/00021 & PI17/01799), AstraZeneca, Bristol-Myers Squibb, Janssen, and Novartis; has received consulting fees from AstraZeneca, Bayer, Bristol-Myers Squibb-Pfizer, and Novartis; and has received speaking fees or support for attending scientific meetings from AstraZeneca, Bayer, Bristol-Myers Squibb-Pfizer, Novartis, and MEDSCAPE-the heart.org.S
    corecore